LB series asphalt plant has a large production capacity and can achieve continuous and efficient production. It adopts advanced mixing technology and control system, which can quickly mix asphalt, aggregate and filler to improve production efficiency.
Item/Model | LB500 | LB800 | LB1000 | LB1200 | LB1500 | LB2000 | LB3000 | LB4000 | LB5000 |
Rated Capacity (t/h) | 40t/h | 64t/h | 80t/h | 96t/h | 120t/h | 160t/h | 240t/h | 320t/h | 400t/h |
Water Content | <5% | ||||||||
Drying Drum Size (m) | 1.2×5.2 | 1.2×5.2 | 1.5×6.65 | 1.6×7.8 | 1.8X7.9 | 2.2X9 | 2.55X10 | 2.8X11.6 | 3X12 |
Drying Drum Capacity | 65t/h | 65t/h | 80t/h | 100t/h | 120t/h | 160t/h | 240t/h | 320t/h | 400t/h |
Burner | Diesel/diesel-heavy oil purpose/pulverized coal/gas/fuel-gas purpose (optional for clients) | ||||||||
Maximum Burning Capacity of Burner | 300kg/h | 450kg/h | 550kg/h | 750kg/h | 1000kg/h | 1250kg/h | 1700kg/h | 2250kg/h | 2800kg/h |
Dust Collection System | Level I cyclone/gravity dust collector + Level II bag dust collector | ||||||||
Filtering Area of Bag Dust Collector (m2) | 256 | 384 | 448 | 624 | 896 | 1200 | 1400 | ||
Hot Aggregate Hoister | Board chain hoisting /td> | ||||||||
Maximum Capacity of Hot Aggregate Hoister | 70t/h | 70t/h | 90t/h | 105t/h | 125t/h | 175t/h | 260t/h | 360t/h | 420t/h |
Maximum Capacity of Vibrating Screen | 70t/h | 70t/h | 90t/h | 105t/h | 125t/h | 175t/h | 260t/h | 360t/h | 420t/h |
Mixer (Dual-horizontal Shaft Batch Type) | 500kg/batch | 800kg/batch | 1000 kg/batch | 1200 kg/batch | 1500 kg/batch | 2000 kg/batch | 3000 kg/batch | 4000 kg/batch | 5000 kg/batch |
Mixing Drum Drive | Driven by dual-gear-motor (gear synchronization) | ||||||||
Filler Supply System | Bucket hoisting | ||||||||
Maximum Capacity of Filler Hoister | 20t/h | 40t/h | 50t/h | ||||||
Weighing Accuracy /td> | Aggregate: ±0.5% filler: ±0.25% Bitumen: ±0.25% | ||||||||
Bitumen Supply System | Instantaneous electric heating/Heat transfer oil heating type (optional coal/fuel/gas) | ||||||||
Fuel Supply System | Optional coal/fuel/gas | ||||||||
Overall Power (about Kw)Exclude Overall Environmental Protection Configuration | 190kw | 202kw | 250kw | 270kw | 340kw | 500kw | 650kw | 810kw | 920kw |